L
o
a
d
i
n
g
.
.
.
Infrastructure
 

Heat Treatment Unit at Taloja

Specification Description
No. of Furnaces 5
Furnace type Front opening box (Batch type)
Max. Operating temperature 1200ºC
Max. Charge dimensions (mm) 2400 L * 1500 B * 1000 H for 4 Furnace
3000 L * 2300 B * 1000 H for 1 Furnace
Max. Charge weight 2500 kgs
Max. Quench delay 90 seconds
Temperature Control Accuracy ± 8ºC
Furnace Insulation Ceramic fiber blanket
Quenching tanks & Capacity 2 (Oil & water) – 20 KL each

Other Details :

  • PNG (Natural Gas) fired Furnaces.
  • All Temperature Instruments, PID Controllers, Thermocouples & Furnaces are Calibrated by NABL approved agencies, as per
    • API 6A (Annexture-M)
    • AMS 2750 latest edition,
  • Strip chart type Time-temperature graph recorder installed.
  • Two thermocouples installed in each furnace.
  • 62.5 KVA Diesel generator for back-up.
  • Rotatory manipulator for the movement of material
  • Brinell Hardness Machines for Quality control, by NABL approved agency.
Request a Quote